PRODUCT
Only Transformers. Built to Perfection.
CAST-RESIN TRANSFORMERS

Amorphous-Core Transformers
Energy-saving oil-immersed transformer with more than 75 percent reduction of no-load loss using amorphous metal instead of silicone sheet.
No-load loss reduction
Minimal no-load loss by amorphous structure and super-laminate metal pin materials.
Economic efficiency
Operation and maintenance cost decrease and life extension expectation of transformer by the loss reductio.
Harmonic wave reduction
High Efficiency and compactification by excellent magnetic characteristics in the high frequency and harmonic wave band.
| Applicable Standard | IEC 60076-11, KS C 4311 | ||||
| Frequency | 50, 60Hz | ||||
| Insulation class | B or F | ||||
| Temperature rise | 80℃ or 100℃ | ||||
| BIL (kV) | System Voltage | 24 | 7.2 | 3.6 | 0.6 below |
| Power frequency withstand voltage | 50 | 20 | 10 | 3 | |
| Impulse Voltage | 95 | 40 | 20 | - | |
| Primary voltage (kV) | 22.9 | 6.6 | 33.3 | 0.6 below | |
| Tap voltage (kV) | F23.9-R22.9- | F6.9-R6.6-6.3- | F3.45-R3.3-3.15- | - | |
| 21.9-20.9-19.9 | 6.0-5.7 | 3.0-2.85 | |||
| Secondary voltage (kV) | 6.6, 3.3, 0.48, 0.44, 0.38, 0.22 | ||||
Amorphous-Core Transformers
A dry-type transformer encapsulated with epoxy resin, providing high reliability, safety, and environmental protection. It is suitable for indoor installation where fire safety and low maintenance are required.
Fire Safety & Environmental Protection
Non-flammable and self-extinguishing characteristics eliminate the risk of fire and oil leakage, making it ideal for installation in buildings, subways, hospitals, and commercial facilities.
High Reliability
Excellent resistance to moisture, dust, and contaminants ensures stable operation even in harsh environments.
Low Maintenance
With no oil required, maintenance is minimized, reducing operating costs and improving long-term reliability.
Compact Design
Optimized insulation structure enables a compact footprint and efficient space utilization.
Applicable Standards | IEC 60076-11, KS C 4311 | ||||
Frequency | 50 / 60 Hz | ||||
Insulation Class | B or F | ||||
Temperature Rise | 80℃ or 100℃ | ||||
Insulation Level (BIL) | System Voltage (kV) | 24 | 7.2 | 3.6 | ≤ 0.6 |
Power Frequency Withstand Voltage (kV) | 50 | 20 | 10 | 3 | |
Lightning Impulse Voltage (kV) | 95 | 40 | 20 | - | |
Primary Voltage (kV) | 22.9 / 6.6 / 33.3 / ≤ 0.6 | ||||
Tap Changer Range (kV) | 22.9 kV | 23.9 - 22.9 - 21.9 - 20.9 - 19.9 | |||
| 6.6 kV | 6.9 - 6.6 - 6.3 - 6.0 - 5.7 | ||||
| 3.3 kV | 3.45 - 3.3 - 3.15 - 3.0 - 2.85 | ||||
Secondary Voltage (kV) | 6.6 / 3.3 / 0.48 / 0.44 / 0.38 / 0.22 | ||||

Add. 344-21 Maebawi-ro, Jangan-myeon, Manse-gu, Hwaseong-si, Gyeonggi-do, Republic of Korea.
Tel. +82-31-355-9977
Fax. +82-31-356-1452
E-mail. sales@sjtr.co.kr
Copyright(C)SUNGJIN. All Rights Reserved.
Sungjin General Electric Co.,Ltd.
Add. 344-21 Maebawi-ro, Jangan-myeon, Hwaseong-si, Gyeonggi-do, Republic of Korea
Tel. +82-31-355-9977 | Fax. +82-31-356-1452 | E-mail. sales@sjtr.co.kr
Copyright(C)SUNGJIN. All Rights Reserved.